The key (but unoriginal) concept for this installation was to: "replace" the front doorbell button which activates the Chime module within the intercom system master station with a relay switch (see the wire diagram).
(1) I turned off the circuit breaker to my intercom system.
(2) I repurposed the two front door intercom wires running from the "COMM" and "FRONT" terminals on the “Chime Module” at the back of the Nutone master station because they run from the station to the front doorbell.
(3) I connected a wire from one terminal of the 16VAC transformer to the low voltage input coil on the NEW relay and attached the other end of the low voltage input coil on the NEW relay to one of the old repurposed front door intercom wires that ran to the front door. I connected this old repurposed wire to a Ring Doorbell terminal.
(4) I attached the second old repurposed front door intercom wire to the second transformer terminal and attached that same old wire to the front door on a second Ring Doorbell terminal.
(5) Finally, I used a wire to connect one of the normally open switch terminals (N/O) on the NEW relay to the (common) COMM terminal on the Nutone Chime module (after detaching the old connection) and I used a second wire to connect the other normally open terminal (N/O) on the NEW relay to the (front door) FRONT terminal on the Nutone Chime module (after detaching the old connection).
(6) Turned on the circuit breaker to the intercom system and performed an In-home Chime Setting as directed using the Ring app.
The Ring doorbell battery maintains charge and worked just fine. The old doorbell wires are NOT powered. Therefore, they were left unattached (cap them if it makes you feel better).
Note: Picking the right relay can be tricky because my system runs off a single Nutone 105T, AC transformer (16VAC @ 15 watts) and I did not want to replace it nor install a second transformer.
After some online research, I found two relay choices that seemed reasonable: a **24VAC relay** -_uxcell A14071800ux0297 35mm DIN Rail DPDT 8P General Purpose Power Relay AC 24V Coil W Socket and a RIBU1C Enclosed Relay (10 Amp SPDT with 10-30 Vac/dc/120 Vac Coil) from Functional Devices, Inc. Tried both but the uxcell 24VAC relay seemed to work better in my hands. See my wire diagram. The Ring Doorbell activates the NEW relay which activates the Chime module and I hear the doorbell chime throughout the whole house as before.
The OLD front doorbell/speaker wall box is large with this Nutone intercom system. I found the appropriate cover plate made specifically for this purpose with a small opening thru which to feed wires to connect to the Ring doorbell. The plate was purchased from Kyle Switch Plates (https://www.kyleswitchplates.com). This cover plate allowed for the wiring and mounting of the new Ring doorbell.
15994 •
0 •
8 •
09-11-2020 02:06:25
Responses (3)
0
06-03-2021 01:53:53
0
10-03-2021 03:30:46
1
21-05-2021 10:29:05
0
06-09-2021 12:57:20
•
0
18-04-2022 20:12:08
•
Log in or create your Ring account to post a question and join in the on the conversation.
Community Resources
Most Helpful Members
View All
©2024 Ring LLC or its affiliates
Mattvp
1
28-12-2020 01:41:47
•