Ring-Intercom

Browse posts, check compatibility, comment, and join in the discussion about Ring Intercom.

U
BPT YKP/200
troubleshooting

I have a BPT YKP/200 - ring says it isn’t compatible but I am giving it a go following /300 instructions. It worked once and now it just says updating. Any advice on connecting the cables/and or maybe just replacing the whole intercom - is it easy to do!

102

3

0

16-08-2024 19:19:38

Responses (3)

  • E

    Hi, our team advises against using the Intercom with any traditional intercoms that are not listed in our official list of compatible devices. It's crucial to ensure compatibility to prevent any potential damage to your traditional intercom system. Our development team has thoroughly tested and confirmed compatibility with the devices listed on our official compatibility list. We value the safety and functionality of your intercom system, so we strongly recommend sticking to the devices that have been verified by our team. This will help ensure a smooth and reliable experience with Ring Intercom.

    0

    23-08-2024 08:56:39

    • U

      The compatibility checker shows VKP/200+YV(YVC) as compatible (but strangely VKP/200 shown as incompatible).

      I haven’t purchased ring intercom yet but I also have YKP/200 so I am doing some research.

      I think it’s highly likely compatible. 

      YKP/200 is one of the intercoms in BPT Lynea 200 series and connects to PSU VA/200. In that series, there is another model YVM/200 connects in the same way according to VA/200 manual. Checking installation manual of VKP/200 and YVM/200 they have exactly same terminals/ports (at least terminals 3-9 which handles video at 3&4, audio at 8&9, incoming call at 7, ground at 5, door unlock at 9, enough for our purpose).

      And YVM/200 is listed as a compatible model. 

      So I suspect using the wiring of YVM/200 will work for VKP/200 (if there is no wiring instruction in the app foe VKP/200+YV). I will buy one and try it out at a later stage.

      References:

      https://doorentrydirect.com/media/product_attach_files/v/a/va200_01.pdf?srsltid=AfmBOopc0myYZr7Q96km4-q2zGunCFMKkSkNCWb6jAms9Za0fgnebnaE https://doorentrydirect.com/acrobat/bpt/instructions/bpt_ykp200+yv%XXXXXXXXXX%2004_07%20.pdf?srsltid=AfmBOoqi_ZcF4tXilf-8qsAkrQLn2AAtxTjYlX0Tk6ati_7zTzcYKiNh 

      0

      03-12-2025 20:06:40

      • U

        I can confirm YKP/200 is compatible, with below the wiring, it works very well. I don't know if you can follow /300 instructions, I believe /300 has changed to a digital bus model so should be very different.

        0

        01-01-2026 21:32:33